Commander SE Advanced User Guide
153
Issue Number: 4
11.2 RFI Filter Data
RFI filters are available as optional extra parts where required.
Table 11-1 Commander SE Size 1
Table 11-2 Commander SE Size 2 - 200V, 26A, 1 phase
Table 11-3 Commander SE Size 2 - 200 / 400V, 16A, 3 phase
Table 11-4 Commander SE Size 2 - 200 / 400V, 16A, 3 phase
Table 11-5 Commander SE Size 2 - 200V, 26A, 3 phase
Table 11-6 Commander SE Size 3 - 200V, 30A
Table 11-7 Commander SE Size 3 - 400V, 17A
Table 11-8 Commander SE Size 4
Table 11-9 Commander SE Size 5
Used with
Filter Part
No
Filter Type
Mounting
Max motor cable length
Standard Low leakage Low cost
Footprint Side
m
ft
SE11200025 to
SE11200075
4200-6101
Y
Y
20
66
4200-6102
Y
Y
Y
75
246
4200-6103
Y
Y
Y
15
49
Used with
Filter Part
No
Filter Type
Mounting
Max motor cable length
Standard Low leakage Low cost
Footprint Side
m
ft
SE2D200075 to
SE2D200220
4200-6201
Y
Y
Y
100
330
4200-6204
Y
Y
50
164
4200-6205
Y
Y
Y
15
49
Used with
Filter Part
No
Filter Type
Mounting
Max motor cable length
Standard Low leakage Low cost
Footprint Side
m
ft
SE2D200075 to
SE2D200220
4200-6202
Y
Y
Y
100
330
4200-6304
Y
Y
15
49
4200-6207
Y
Y
Y
45
148
Used with
Filter Part
No
Filter Type
Mounting
Max motor cable length
Standard Low leakage Low cost
Footprint Side
m
ft
SE23400075 to
SE23400400
4200-6202
Y
Y
Y
100
330
4200-6304
Y
Y
15
49
4200-6207
Y
Y
Y
20
66
Used with
Filter Part
No
Filter Type
Mounting
Max motor cable length
Standard Low leakage Low cost
Footprint Side
m
ft
SE23200400
4200-6203
Y
Y
Y
100
330
4200-6303
Y
Y
20
66
4200-6209
Y
Y
Y
45
148
Used with
Filter Part No
Filter Type
Mounting
Max motor cable length
Standard
Low cost
Footprint
Side
m
ft
SE33200550 to
SE33200750
4200-6302
Y
Y
Y
100
330
4200-6303
Y
Y
15
49
Used with
Filter Part No
Filter Type
Mounting
Max motor cable length
Standard
Low cost
Footprint
Side
m
ft
SE33400550 to
SE33400750
4200-6301
Y
Y
Y
100
330
4200-6304
Y
Y
15
49
Used with
Filter Part No
Filter Type
Mounting
Max motor cable length
Standard
Low cost
Footprint
Side
m
ft
SE43401100 to
SE43401500
4200-6401
Y
Y
Y
100
330
4200-6402
Y
Y
15
49
SE43401850
4200-6403
Y
Y
Y
100
330
4200-6404
Y
Y
20
66
Used with
Filter Part No
Filter Type
Mounting
Max motor cable length
Standard
Bookcase
m
ft
SE53402200
4200-6116
Y
Y
100
330
SE53403000
4200-6117
Y
Y
100
330
SE53403700
4200-6106
Y
Y
100
330
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...