172
Commander SE Advanced User Guide
Issue Number: 4
12.11 Motorised potentiometer set-up
The Commander SE has the possibility to emulate a motorised potentiometer by simply supplying two logic input signals to
increase or decrease the potentiometer. The output of the potentiometer may be routed to control any of the drives non-bit
parameters such as speed, torque or current limit. Additionally the function may be configured to reset upon power cycling, or
to memorise its value.
Parameter set-up
8.39
= 1
Disable auto set-up of terminals 12 and 13.
8.31
= 0
Digital input 1 (terminal 8) set as an input.
8.21
=
9.28
Digital input 1 (terminal 8) assigned as RESET for motorised potentiometer.
8.25
=
9.26
Digital input 5 (terminal 12) assigned as motorised potentiometer increase.
8.26
=
9.27
Digital input 6 (terminal 13) assigned as motorised potentiometer decrease.
9.23
= ?
This adjusts the rate of increase / decrease.
7.10
= 0
Analog input 1 not used.
9.25
=
1.36
Motorised potentiometer destination assigned to analog reference 1.
Perform a Save routine:
xx.00
= 1000 and press red Stop / Reset button on the drive.
RESET
1
0
DECREASE
INCREASE
+24V
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...