54
Commander SE Advanced User Guide
Issue Number: 4
This parameter permanently enables the Stop button on the drive such that the drive will always stop when the stop button is
pressed.
This parameter enables the Fwd/Rev button on the drive.
Setting this parameter to 0 will disable the drive. It must be at 1 for the drive to run.
*Units: Currency/kWh
When this parameter is set up correctly for the local currency,
6.26
will give an instantaneous read out of running cost.
Used to reset parameters
6.24
and
6.25
back to zero.
Together with the next parameter the drive records the amount of time the drive has been running since it left the
manufacturing plant.
Together with the previous parameter the drive records the amount of time the drive has been running since it left the
manufacturing plant.
Drive power consumption meter. This can be reset to zero by setting parameter
6.17
.
6.12
Keypad stop key enable
Ú
0 or 1
Ö
Europe> 0
USA> 1
RW
Bit
6.13
Keypad fwd / rev key enable
Ú
0 or 1
Ö
0
RW
Bit
6.14
Unused parameter
6.15
Drive enable
Ú
0 or 1
Ö
1
RW
Bit
6.16
Electricity cost / kWh
Ú
0.0 ~ 600.0
Ö
1
*
RW
Uni
6.17
Power consumption meter reset
Ú
0 or 1
Ö
0
RW
Bit
6.18 ~
6.21
Unused parameters
6.22
Run time log. years / days
Ú
0 ~ 9.364
Ö
years/days
RO
Uni
S
P
6.23
Run time log. hours / minutes
Ú
0 ~ 23.59
Ö
hours/mins
RO
Uni
S
P
6.24
Power meter MWh
Ú
0 ~ 999.9
Ö
MWh
RO
Uni
S
P
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...