Commander SE Advanced User Guide
73
Issue Number: 4
3.9 Menu 9: Programmable logic and motorised pot
Parameter
Range
Type
Default
Setting
Default
Rate
9.01
Prog. logic function output indicator
0 or 1
RO
Bit
P
L3
9.02
Not used
9.03
Motorised pot output indicator
±
100.0%
RO
Bi
S
P
L3
9.04
Prog. logic function 1 source
parameter
0.00 ~ 21.51
Menu.parameter
RW
Uni
P
0.00
L3
9.05
Prog. logic function source 1 invert
0 or 1
RW
Bit
0
L3
9.06
Prog. logic function 2 source
parameter
0.00 ~ 21.51
Menu.parameter
RW
Uni
P
0.00
L3
9.07
Prog. logic function source 2 invert
0 or 1
RW
Bit
0
L3
9.08
Prog. logic function output invert
0 or 1
RW
Bit
0
L3
9.09
Prog-logic function delay
0.0 ~ 25.0 secs
RW
Uni
0
L3
9.10
Prog-logic function destination
0.00 ~ 21.51
Menu.parameter
RW
Uni
R
P
0.00
I
9.11~
9.20
Not used
9.21
Motorised pot zero start select
0 or 1
RW
Bit
0
I
9.22
Motorised pot bipolar select
0 or 1
RW
Bit
0
L3
9.23
Motorised pot rate
0 ~ 250 secs
RW
Uni
20
B
9.24
Motorised pot scale factor
0.00 ~ 2.50
RW
Uni
1.00
B, I
9.25
Motorised pot destination
0.00 ~ 21.51
Menu.parameter
RW
Uni
R
P
0.00
I
9.26
Motorised pot. up
0 or 1
RO
Bit
L3
9.27
Motorised pot.down
0 or 1
RO
Bit
L3
9.28
Motorised pot.reset
0 or 1
RW
Bit
0
L3
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...