74
Commander SE Advanced User Guide
Issue Number: 4
This parameter indicates the output state of the programmable logic function. The output of the logic function can be routed to
the digital output if required, by setting the appropriate digital output source in menu 8.
Indicates the level of the motorised pot prior to scaling. If parameter
9.21
is set to 1 this parameter is set to 0 at power up.
*Units: Menu.Parameter
This source parameter defines the parameter to be sourced into logic input 1 of the programmable logic function 1.
Only a bit parameter can be programmed as an input.
If both inputs to the logic function are non valid, then the logic output will always be a 0.
If one input source is left at its default value of 0.00 or one input source is non valid, its input is taken as 1 so that the valid
input on the other input source can pass through the function gate.
Setting this parameter to a 1 causes the input sense from logic function 1 source parameter to be inverted.
*Units: Menu.Parameter
This source parameter defines the parameter to be sourced into logic input 2 of the programmable logic function 1.
Only a bit parameter can be programmed as an input.
If both inputs to the logic function are non valid, then the logic output will always be a 0.
If one input source is left at its default value of 0.00 or one input source is non valid, its input is taken as 1 so that the valid
input on the other input source can pass through the function gate.
Setting this parameter to a 1 causes the input sense from logic function 2 source parameter to be inverted.
Setting this parameter to a 1 causes the output from the logic to be inverted.
This parameter introduces a delay into the switching of the logic output of logic function 1. The delay is on an output transition
from a 0 to a 1 only, such that there is a delay on the output becoming active, but not on the output becoming inactive. The
delay parameters are primarily there to ensure that the output condition is a genuine condition (by being present for a period
of time) and not just a temporary one.
9.01
Programmable logic function output indicator
Ú
0 or 1
Ö
0
RO
Bit
P
9.02
Unused parameter
9.03
Motorised pot output indicator
Ú
±
100.0
Ö
%
RO
Bi
S
P
9.04
Prog. logic function 1 source parameter
Ú
0.00 ∼ 21.51
Ö
*
0.00
RW
Uni
P
9.05
Prog. logic function source 1 invert
Ú
0 or 1
Ö
0
RW
Bit
9.06
Prog. logic function 2 source parameter
Ú
0.00 ~ 21.51
Ö
0.00
*
RW
Uni
P
9.07
Prog. logic function source 2 invert
Ú
0 or 1
Ö
0
RW
Bit
9.08
Prog. logic function output invert
Ú
0 or 1
Ö
0
RW
Bit
9.09
Prog. logic function delay
Ú
0.0 ~ 25.0
Ö
0
s
RW
Uni
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...