Commander SE Advanced User Guide
77
Issue Number: 4
3.10 Menu10: Status and trips
Parameter
Range
Type
Default
Setting
Update Rate
10.01 Drive healthy indicator
0 or 1
RO
Bit
P
L1 (set),
B (clear)
10.02 Drive running indicator
0 or 1
RO
Bit
P
B
10.03 At zero speed indicator
0 or 1
RO
Bit
P
BF
10.04 At or below min. speed indicator
0 or 1
RO
Bit
P
BF
10.05 Below at speed window indicator
0 or 1
RO
Bit
P
BF
10.06 At speed indicator
0 or 1
RO
Bit
P
BF
10.07 Above at speed window indicator
0 or 1
RO
Bit
P
BF
10.08 At 100% load indicator
0 or 1
RO
Bit
P
B
10.09 Current limit active indicator
0 or 1
RO
Bit
P
B
10.10 Motor regenerating indicator
0 or 1
RO
Bit
P
B
10.11 Dynamic brake active indicator
0 or 1
RO
Bit
P
B
10.12 Dynamic brake alarm indicator
0 or 1
RO
Bit
P
B
10.13 Direction demanded indicator
0 or 1
RO
Bit
P
B
10.14 Direction running indicator
0 or 1
RO
Bit
P
B
10.15 AC supply loss indicator
0 or 1
RO
Bit
P
B
10.16 Not used
10.17 Motor current overload indicator
0 or 1
RO
Bit
P
B
10.18 Drive temperature alarm indicator
0 or 1
RO
Bit
P
B
10.19 General drive alarm
0 or 1
RO
Bit
B
10.20 Last trip
0 ~ 200
RO
Txt
S
P
B
10.21 Second last trip
0 ~ 200
RO
Txt
S
P
B
10.22 Third last trip
0 ~ 200
RO
Txt
S
P
B
10.23 Fourth last trip
0 ~ 200
RO
Txt
S
P
B
10.24 Fifth last trip
0 ~ 200
RO
Txt
S
P
B
10.25 Sixth last trip
0 ~ 200
RO
Txt
S
P
B
10.26 Seventh last trip
0 ~ 200
RO
Txt
S
P
B
10.27 Eighth last trip
0 ~ 200
RO
Txt
S
P
B
10.28 Ninth last trip
0 ~ 200
RO
Txt
S
P
B
10.29 Tenth last trip
0 ~ 200
RO
Txt
S
P
B
10.30 Max full power braking time
0.0 ~ 400.0
secs
RW
Uni
0 B
10.31 Max full power braking period
0.0 ~ 25.0 mins
RW
Uni
0
B
10.32 External trip
0 or 1
RO
Bit
BF
10.33 Drive reset
0 or 1
RW
Bit
0
L3
10.34 No of auto-reset attempts
0 ~ 5
RW
Uni
0
B
10.35 Auto-reset time delay
0.0 ~ 25.0 secs
RW
Uni
1.0
B
10.36
Hold drive healthy until last auto-
reset attempt
0 or 1
RW
Bit
0
B
10.37 Stop drive on non important trips
0 or 1
RW
Bit
0
B
10.38 User trip
0 ~ 200
RW
Uni
P
0
B
10.39 Braking energy overload accumulator
0.0 ~ 100.0%
RO
Uni
P
B
10.40 Status word
0 ~ 32767
RO
Uni
P
B
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...