Commander SE Advanced User Guide
Issue Number: 4
*Units: Menu.Parameter
Destination parameters define the parameter each of the programmable inputs is to control. Only Bit parameters which are
not protected can be controlled by the programmable digital inputs. If a non-valid parameter is programmed, the digital input
is not routed anywhere.
Source parameters define the parameter to be represented at the digital output terminal or relay. Only Bit parameters can be
selected as a source for a digital output. If a non-valid parameter is programmed, then the digital output will remain in the
inactive state and the relay will remain in the de-energised state.
This parameter changes the logic polarity on the digital inputs. In its default state the input polarity is positive logic which
requires the digital inputs to be driven high to activate the input. When this parameter is set to a 0, the input polarity is
negative logic which requires the digital inputs to be pulled low to activate the input.
A change to the logic input polarity will only be implemented if the drive is disabled or tripped and the Stop/Reset
key is pressed or a Reset command is given over serial comms. The Run terminals should be open when any
change is implemented.
This parameter is set to 1 for Terminal 8 to be an output and set to a 0 for Terminal 8 to be an input.
8.18~
8.20
Unused parameters
8.21
Digital input 1 destination / output source
8.22
Digital input 2 destination
8.23
Digital input 3 destination
8.24
Digital input 4 destination
8.25
Digital input 5 destination
8.26
Digital input 6 destination
8.27
Relay source
Ú
Source: 0.00 ~ 21.51
Ö
*
RW
Uni
R
P
Terminal
Destination/
source
parameter
Function
Default
parameter
Default description
Comments
8
8.21
Input destination/
Output source
10.03
Zero speed (output)
9
8.22
Input destination
6.29
Enable
See parameter
6.04
for
further set-up information
10
8.23
Input destination
6.30
Run Forward
11
8.24
Input destination
6.32
Run Reverse
12
8.25
Input destination
6.31
Jog
Reference select dependant.
See parameter
1.14
13
8.26
Input destination
1.41
Local / Remote
15 & 16
8.27
Relay source
10.01
Drive Healthy
8.29
Logic input polarity
Ú
0 or 1
Ö
1
RW
Bit
R
P
8.30
Unused parameter
8.31
Activate digital output 1
Ú
0 or 1
Ö
1
RW
Bit
R
NOTE
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...