5.2 Commander SE HF Faults
HF01
SOFTSTARTFAIL
Soft start relay failure detected by DSP (not applicable to SE size 5)
HF02
OIFAILURE
OI trip detected at power up
HF03
FANFAILED
Cooling fan not running (if fitted). No PWM detected by micro
HF70
LEVEL1OVERRUN
User code level 1 overrun
HF71
LEVEL2OVERRUN
User code level 2 overrun
HF72
LEVEL3OVERRUN
User code level 3 overrun
HF73
DSPCOMMS
Communications between processor and DSP not working
HF74
DSPOVERRUN
DSP code overrun
HF83
POWERBOARD CODE Incorrect power board code
HF88
WDOG
User code watchdog failure
HF90
STACKOF
User code stack overflow
HF91
STACKUF
User code stack underflow
HF92
ILLOPCODE
User code illegal opcode
HF96
ILLADDRESS
User code illegal address
HF98
INTCRASH
User code interrupt crash error
These trips codes are internal to the drive and are not caused by the customer. With most of these trips, if the drive is
powered down and back up, the trip will be cleared and the drive will run as normal.
HF01
- If the inrush/softstart relay does not close correctly on power up or opens while the drive is running, the drive will trip
on HF01.
HF02
- If the drive detects an OI.AC - overcurrent trip on power up, the drive will trip on HF02 and not OI.AC
HF03
- If a Commander SE is fitted with a heatsink cooling fan and it stops working, the drive will trip on HF03.
HF70, 71 & 72
- The user interface code (control PCB microprocessor) runs on different priority levels and each level has a
certain time to complete its tasks. If for some reason the code cannot complete its task within the allotted time, it will trip on
HF70, 71 or 72.
HF73
- The 2 microprocessors talk to each other via 2 wire RS485 serial communications. If this internal serial
communication link fails, the drive will trip on HF73.
HF74
- As HF70, 71 & 72 but with the DSP (Digital Signal Processor) on the power PCB.
HF83
- The DSP reads a voltage from the power pcb to determine the correct drive kW size. If this voltage is different to an
expected value, the drive will trip on HF83.
HF88, 90, 91, 92, 96 & 98
- While the user code is running, it is continuously checking that the data it is receiving is valid, the
addresses are valid etc. If it detects a problem, it will trip on one of the trips codes HF88, 90, 91, 92, 96 & 98.
DSP
refers to the Digital Signal Processor that is the microprocessor on the drives power PCB which contains the machine
control software
User code
/
User interface
refers to the microprocessor on the drives control PCB which contains the user interface
software
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...