Commander SE Advanced User Guide
87
Issue Number: 4
Alternatives to pressing the STOP/RESET when in rEAd or Prog modes:
•
Set parameter 10.33 to a 1 via serial communications
•
Set parameter 10.38 to 100 via serial communications
•
Toggle a terminal programmed as a reset terminal
Any parameter values that have been changed via serial communications but not stored in the drives EEPROM
memory will not be stored in the Quickey
When the drive parameters are stored to the Quickey, if the current mode is rEAd or Prog, it is stored in the Quickey as no. If
the current mode is AutO or boot, these are stored as AutO or boot.
The Quickey memory contains drive size specific information. If the contents of the Quickey are copied to a drive of
a different rating to that previously programmed, the drive will trip with the code C.rtg. This signifies that all of the
parameters apart from the drive rating specific parameters have been copied from the Quickey.
The Quickey should only be installed or removed when power to the drive has been switched off.
Different drive ratings
The cloning key can be used to copy parameters between drives with different ratings but certain rating dependant
parameters are not copied to the cloned drive, but are still stored within the cloning key.
Drive Rating has changed
In the event that the ratings are different the parameters are firstly written to the drive and then the drive will trip with C.rtg.
11.42
Parameter cloning
Ú
0 ~ 4
Ö
0
RW
Uni
Txt
R
0
no
Do nothing
1
rEAd
When this is set and the user performs a drive reset by pressing the STOP/RESET key
while the drive is disabled (ih), tripped (tr) or on stand-by (rd), the Quickey contents will
be copied to the drive and parameter
11.42
reset to no (0). These parameters are then
saved automatically by the drive.
2
Prog
When this is set and the user performs a drive reset by pressing the STOP/RESET
key, the Quickey contents will be updated with the current drive EEPROM memory
parameter settings. Parameter
11.42
is also reset to no (0).
3
AutO
When this is set and the user performs a parameter save by pressing the mode button
after adjusting a parameter value, the drives current EEPROM memory parameter
settings are saved in the Quickey.
4
boot
When this is set, it provides exactly the same functionality as Auto but in addition it will
overwrite the drives EEPROM memory parameter settings with the Quickey parameter
settings when the drive is powered up. These parameters are then automatically saved
by the drive. This mode provides a very fast and efficient way of re-programming a
number of drives.
Parameter Description
02.08
Standard ramp voltage
04.07
Current Limit
04.08
Torque Reference
05.07
Motor 1 rated current
06.06
Injection braking level
05.09
Motor 1 rated voltage
05.17
Motor 1 stator resistance
05.23
Motor 1 voltage offset
21.07
Motor 2 rated current
21.09
Motor 2 rated voltage
21.12
Motor 2 stator resistance
21.13
Motor 2 voltage offset
NOTE
NOTE
NOTE
NOTE
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...