Commander SE Advanced User Guide
23
Issue Number: 4
These parameters are made available for control by analog inputs which are required to be frequency references.
The programmed input is automatically scaled such that 100.0% input corresponds to the set maximum speed (
1.06
or
21.01
). Also the 0% input level corresponds to the minimum speed level (
1.07
or
21.02
) if Allow negative digital references
(
1.10
) is not selected.
Although the drive’s analog inputs (
7.01
,
7.02
) cannot provide negative speed references, if the analog input destination
parameters (
7.10
,
7.14
) are directed away from the analog reference parameters (
1.36
,
1.37
), then negative values can be
written to them over the serial interface.
These bits are provided for control by logic input terminals for external reference selection (see parameters
1.14
,
21.03
and
1.15
).
Although parameters 1.41 to 1.47 are Read only parameters, they can be written to but only via a digital input.
1.36
Analog reference 1
1.37
Analog reference 2
Ú
±par 1.06 or ±par 21.01
Ö
Hz
RO
Bi
1.38 ~
1.40
Unused parameters
1.41
Analog reference 2 select
1.42
Preset reference select
1.43
Keypad reference select
1.44
Precision reference select
1.45
Preset select bit 0
1.46
Preset select bit 1
1.47
Preset select bit 2
Ú
0 or 1
Ö
RO
Bit
Allow negative digital
reference operation
(01.10 = 1)
Frequency
1.06
100.0
Input (%)
0
NOTE
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...