4.10 DC Bus information
4.10.1 SE DC Bus levels
* These are the absolute minimum DC voltages that the drive can be supplied with. If the drive is not supplied with at least
this voltage, it will not reset out of a UU trip at power up.
4.10.2 SE DC Bus design
200V drives
400V drives
0V trip level
420V
830V
Braking level
390V
780V
Rated upper level (AC mains +10% x 1.4142)
372V
747V
Rated lower level (AC mains -10% x 1.4142)
255V
484V
*
UV reset level
235V
460V
UV trip level
180V
400V
Standard ramp voltage
2.08
390V
EUR> 750V
USA> 775V
Drive
Bus capacitance
uF
Bus inductance
mH
Drive
Bus capacitance
uF
Bus inductance
mH
SE11200025
390
N/A
SE33200550
1880
0.6
SE11200037
390
N/A
SE33200750
1880
0.6
SE11200055
780
N/A
SE33400550
470
1.7
SE11200075
780
N/A
SE33400750
470
1.7
SE2D200075
940
N/A
SE43401100
1020
0.9
SE2D200110
1410
N/A
SE43401500
1020
0.9
SE2D200150
1410
N/A
SE43401850
1020
0.9
SE2D200220
1880
N/A
SE53402200
4400
0.85
SE23200400
1880
N/A
SE53403000
4400
0.91
SE23400075
235
N/A
SE53403700
4400
0.63
SE23400110
235
N/A
SE23400150
235
N/A
SE23400220
470
N/A
SE23400300
470
N/A
SE23400400
470
N/A
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...