Commander SE Advanced User Guide
35
Issue Number: 4
3.4 Menu 4: Current control
Parameter
Range
Type
Default
Setting
Update
Rate
4.01
Motor current magnitude
0 ~ Imax A
RO
Uni
P
B
4.02
Motor active current
± I max A
RO
Bi
P
B
4.03
Not used
4.04
Current demand
± I max %
RO
Bi
P
B
4.05~
4.06
Not used
4.07
Current limit
0 ~ I max %
RW
Uni
165
B
4.08
Torque reference
± I max %
RW
Bi
0
B
4.09~
4.10
Not used
4.11
Torque mode selector
0 or 1
RW
Bit
0
B
4.12
Not used
4.13
Current loop proportional gain
0 ~ 250
RW
Uni
20
B
4.14
Current loop integral gain
0 ~ 250
RW
Uni
40
B
4.15
Motor thermal time constant
0 ~ 250 secs
RW
Uni
89
B
4.16
Motor protection mode select
0 or 1
RW
Bit
0
B
4.17
Motor magnetising current
± I max A
RO
Bi
P
B
4.18
Over-riding current limit
0 ~ I max %
RO
Uni
P
B
4.19
Overload accumulator
0 ~ 100%
RO
Uni
P
B
4.20
Drive load indicator
0 ~ I max %
RO
Bi
P
B
4.21
Load indication selector
0 or 1
RW
Uni
Txt
0
B
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...