67
Issue Number: 4
Summary
Terminals 9 to 13 are five programmable digital inputs. Terminal 8 is a digital output that can also be programmed as a digital
input. Also terminal 13 can be programmed as a motor thermistor input.
If an External Trip is required, then one of the terminals should be programmed to control the External Trip parameter (
10.32
)
with the invert set to 1 so that the terminal must be made active for the drive not to trip.
The digital inputs are sampled every 1.5ms and the digital outputs is updated every 21ms.
See Chapter 12
Applications
for set-up examples.
This parameter indicates the input state of the terminal if it is set up as an input, or the output state if it is set up as an output.
For inputs:
0
= in-active
1
= active
When programmed as a digital output, this terminal is not affected by the logic polarity.
These parameters indicate the input state of the terminal.
0
= in-active
1
= active
This parameter indicates the state of the drive relay. 0= de-energised, 1=energised.
Setting these parameters to a 1 causes the input sense to the destination parameter to be inverted or the output sense from
the source parameter to be inverted.
8.01
Digital input / output 1 (Terminal 8)
Ú
0 or 1
Ö
RO
Bit
P
8.02
Digital input 2 (Terminal 9)
8.03
Digital input 3 (Terminal 10)
8.04
Digital input 4 (Terminal 11)
8.05
Digital input 5 (Terminal 12)
8.06
Digital input 6 (Terminal 13)
Ú
0 or 1
Ö
RO
Bit
P
8.07
Relay output indicator (Terminals 15 and 16)
Ú
0 or 1
Ö
RO
Bit
P
8.08~
8.10
Unused parameters
8.11
Digital input / output 1 invert
8.12
Digital input 2 invert
8.13
Digital input 3 invert
8.14
Digital input 4 invert
8.15
Digital input 5 invert
8.16
Digital input 6 invert
8.17
Relay state invert
Ú
0 or 1
Ö
0
RW
Bit
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...