Commander SE Advanced User Guide
61
Issue Number: 4
3.7 Menu 7: Analog inputs and outputs
Parameter
Range
Type
Default
Setting
Update
Rate
7.01
Analog input 1 (Terminal 2)
0 ~ 100.0%
RO
Uni
P
L2
7.02
Analog input 2 (Terminal 5)
0 ~ 100.0%
RO
Uni
P
L2
7.03
Not used
7.04
Heatsink temperature
0 ~ 100
°
C
RO
Uni
P
B
7.05~
7.07
Not used
7.08
Analog input 1 scaling
0.00 ~ 2.50
RW
Uni
1.0
B, I
7.09
Analog input 1 invert bit
0 or 1
RW
Bit
0
L2
7.10
Analog input 1 destination parameter
0.00 ~ 21.51
Menu.parameter
RW
Uni
R
P
P1.36
I
7.11
Analog input 2 mode selector
(0)0 ~ 20
(1)20 ~ 0
(2)4 ~ 20
(3)20 ~ 4
(4)4 ~ .20
(5)20 ~ .4
RW
Uni
Txt
(4)4-.20
L2
7.12
Analog input 2 scaling
0.00 ~ 2.50
RW
Uni
1.0
B, I
7.13
Analog input 2 invert bit
0 or 1
RW
Bit
0
L2
7.14
Analog input 2 destination parameter
0.00 ~ 21.51
Menu.parameter
RW
Uni
R
P
P1.37
I
7.15~
7.18
Not used
7.19
Analog output source selector
(Terminal 6)
0.00 ~ 21.51
Menu.parameter
RW
Uni
P
2.01-
Post ramp
reference
B, I
7.20
Analog output scaling
0.00 ~ 2.50
RW
Uni
1.0
L3
7.21~
7.27
Not used
7.28
Current loop loss indicator
0 or 1
RO
Bit
P
L2
7.29~
7.32
Not used
7.33
Analog output select
(0)Fr
(1)Ld
(2)Adv
RW
Uni
Txt
R
(0)Fr
B
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...