20
Commander SE Advanced User Guide
Issue Number: 4
These flags are controlled by the drive sequencer defined in Menu 6. They select the appropriate reference as commanded
by the drive logic.
This parameter is used to select a speed reference for motor 1 as follows:
0
A1.A2
Analog voltage input on terminal 2 and analog current input on terminal 5 selected by terminal 12. Jog
selected by terminal 13.
1
A1.Pr
Analog voltage input on terminal 2 and three preset speeds selected by terminals 12 and 13.
2
A2.Pr
Analog current input on terminal 5 and three preset speeds selected by terminals 12 and 13.
3
Pr
4 preset speeds selected by terminals 12 and 13.
4
PAd
Keypad Control.
5
PrC
Precision reference
Automatic set-up
As parameter
05
is changed from A1.A2 to A1.Pr etc. through the drives keypad, parameter
1.14
will change accordingly as
per the table below.
Also the destination parameters of terminals 12 and 13 will change accordingly as long as
8.39
= 0 - automatic set-up is
enabled.
PrC cannot be selected from parameter 05 through the drives keypad although it will be displayed if parameter 1.14
is set to 5.
Advanced set-up
When
1.14
is set to 0, the reference selected can also depend on the state of bit parameters
1.41
to
1.44
. These bits are
controlled by digital inputs such that references can be selected by external control. If any of the bits are set, the appropriate
reference is selected (indicated by
1.49
). If more than 1 bit is set the highest number will have priority.
In analog reference 1 and analog reference 2 modes, a preset speed will be selected instead of analog reference 1 or
analog reference 2 if the preset speed selected is any other than preset speed 1 even if the preset reference, 1.42, is
not selected. This is because of the easy set-up modes that give the user the flexibility to select between analog
reference 1 and 3 preset speeds, or analog reference 2 and 3 presets speed with only 2 digital inputs.
1.11
Reference enabled indicator
1.12
Reverse selected indicator
1.13
Jog selected indicator
Ú
0 or 1
Ö
RO
Bit
P
1.14
Reference selector
Ú
0 ~ 5
Ö
EUR> 0
USA> 4
RW
Uni
Txt
Parameter 05
Parameter 1.14
Terminal 12
destination
Terminal 13
destination
Parameter 1.49
A1.A2
0
1.41
6.31
1
A1.Pr
1
1.45
1.46
1
A2.Pr
2
1.45
1.46
2
Pr
3
1.45
1.46
3
PAd
4
4
PrC
5
5
Parameter
1.41
Parameter
1.42
Parameter
1.43
Parameter
1.44
Frequency reference
selected
Parameter
1.49
0
0
0
0
Analog reference 1 (A1)
1
1
0
0
0
Analog reference 2 (A2)
2
x
1
0
0
Preset reference (Pr)
3
x
x
1
0
Keypad reference (PAd)
4
x
x
x
1
Precision reference (Prc)
5
NOTE
NOTE
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...