Further data for the filters is given in the following tables:
Table 11-10 Commander SE Size 1
Table 11-11 Commander SE Size 2
Table 11-12 Commander SE Size 3
*Also used on Size 2 units.
Table 11-13 Commander SE Size 4
Table 11-14 Commander SE Size 5
Discharge resistors
1.5M
Ω
in a star connection between phases with star point connected by a 680k
Ω
resistor to ground.
This may cause an earth leakage indication in monitored ungrounded power systems such as IT systems.
For tables 11-9 to 13-14, please be aware of the following:
Weight
is unpacked weight.
Worst case leakage current
:
Single phase filters - when the neutral is disconnected.
Three phase filters - when an input phase is disconnected.
The data is given for an input voltage of 230V, 50Hz.
Part
Number
Maximum
Power
Losses
IP Rating
Weight
Operational
Leakage
Current
Worst Case
Leakage
Current
Filter Terminal
Tightening Torque
Filter
current
rating
W
kg
lb
mA
mA
Nm
lb ft
A
4200-6101
6
21
0.49
1.1
4.0
8.0
0.8
0.6
12
4200-6102
6
20
0.60
1.3
40.7
77.5
0.8
0.6
12
4200-6103
6
21
0.60
1.3
2.9
5.7
0.8
0.6
12
Part
Number
Maximum
Power
Losses
IP Rating
Weight
Operational
Leakage
Current
Worst Case
Leakage
Current
Filter Terminal
Tightening Torque
Filter
current
rating
W
kg
lb
mA
mA
Nm
lb ft
A
4200-6201
10.1
20
1.2
2.6
89
128
0.8
0.6
26
4200-6202
10.1
20
1.1
2.4
45.7
184.2
0.8
0.6
16
4200-6203
15.4
20
1.3
2.9
26.4
106.3
0.8
0.6
26
4200-6204
6
20
0.7
1.5
29.5
58.9
0.8
0.6
26
4200-6205
10.1
20
1.2
2.6
2.8
5.7
0.8
0.6
26
4200-6207 10.1
20
1.1
2.4
3
18.3
0.8
0.6
16
4200-6209
15.4
20
1.3
2.9
2.6
15.5
0.8
0.6
26
Part
Number
Maximum
Power
Losses
IP Rating
Weight
Operational
Leakage
Current
Worst Case
Leakage
Current
Filter Terminal
Tightening Torque
Filter
current
rating
W
kg
lb
mA
mA
Nm
lb ft
A
4200-6301
12.4
20
1.6
3.5
45.7
184.2
0.8
0.6
17
4200-6302
19.5
20
1.7
3.7
26.4
106.3
0.8
0.6
30
4200-6303
*
10.8
20
0.8
1.7
14.1
68
0.8
0.6
30
4200-6304
*
6.1
20
0.6
1.3
33
148
0.8
0.6
17
Part
Number
Maximum
Power
Losses
IP Rating
Weight
Operational
Leakage
Current
Worst Case
Leakage
Current
Filter Terminal
Tightening Torque
Filter
current
rating
W
kg
lb
mA
mA
Nm
lb ft
A
4200-6401
26.1
20
3.1
6.8
29.4
280
2.2
1.6
33
4200-6402
11.7
20
1.1
2.4
14.1
68
2.2
1.6
33
4200-6403
30
20
3.1
6.8
38
220
2.2
1.6
37
4200-6404
16
20
1.2
2.6
24.5
132
2.2
1.6
37
Part
Number
Maximum
Power
Losses
IP
Rating
Weight
Operational
Leakage
Current
Worst Case
Leakage
Current
Terminal
Torques
Ground
Connection
Torque
Filter
current
rating
W
kg
lb
mA
mA
Nm
lb ft
Nm
lb ft
A
4200-6116
12.8
20
3.8
9
31
143
4.5
3.3
2.2
1.6
50
4200-6117
14.3
20
3.8
9
29
126
4.5
3.3
4.0
2.9
63
4200-6106
25.5
20
7.8
17
48.5
209
8.0
5.9
9.0
6.6
100
NOTE
NOTE
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...