18
Commander SE Advanced User Guide
Issue Number: 4
3.1 Menu 1: Speed reference selection, limits and filters
* The maximum value is
1.06
or
21.01
.
Parameter
Range
Type
Default
Setting
Update
Rate
1.01
Level of reference selected
±
1000.0 Hz*
RO
Bi
P
L2
1.02
Pre-filter reference
±
Max
RO
Bi
P
L2
1.03
Pre-ramp reference
±
Max
RO
Bi
P
L2
1.04
Not used
1.05
Jog reference
0 ~ 400.0Hz
RW
Uni
1.5
L2
1.06
Maximum speed clamp
0 ~1000.0Hz
RW
Uni
50(EUR)
60(USA)
B
1.07
Minimum speed clamp
0 ~ [1.06]
RW
Uni
0.0
B
1.08~
1.09
Not used
1.10
Allow negative digital references
0 or 1
RW
Bit
0
B
1.11
Reference enabled indicator
0 or 1
RO
Bit
P
L1
1.12
Reverse selected indicator
0 or 1
RO
Bit
P
L1
1.13
Jog selected indicator
0 or 1
RO
Bit
P
L1
1.14
Reference selector
0-5
RW
Uni
Txt
0(EUR)
4(USA)
L2
1.15
Preset selector
0-8
RW
Uni
0
L2
1.16
Not used
1.17
Keypad reference
±
Max
RO
Bi
S
P
0.0
B
1.18
Precision reference
±
1000.0Hz
RW
Bi
0.0
L2
1.19
Precision reference trim
0 ~ 99mHz
RW
Uni
0
L2
1.20
Precision reference update disable
0 or 1
RW
Bit
0
L2
1.21
Preset speed reference 1
±
1000.0Hz
RW
Bi
0.0
L2
1.22
Preset speed reference 2
±
1000.0Hz
RW
Bi
0.0
L2
1.23
Preset speed reference 3
±
1000.0Hz
RW
Bi
0.0
L2
1.24
Preset speed reference 4
±
1000.0Hz
RW
Bi
0.0
L2
1.25
Preset speed reference 5
±
1000.0Hz
RW
Bi
0.0
L2
1.26
Preset speed reference 6
±
1000.0Hz
RW
Bi
0.0
L2
1.27
Preset speed reference 7
±
1000.0Hz
RW
Bi
0.0
L2
1.28
Preset speed reference 8
±
1000.0Hz
RW
Bi
0.0
L2
1.29
Skip frequency 1
0 ~1000.0Hz
RW
Uni
0.0
B
1.30
Skip frequency band 1
0 ~ 5.0Hz
RW
Uni
0.5
B
1.31
Skip frequency 2
0 ~1000.0Hz
RW
Uni
0.0
B
1.32
Skip frequency band 2
0 ~ 5.0Hz
RW
Uni
0.5
B
1.33
Skip frequency 3
0 ~1000.0Hz
RW
Uni
0.0
B
1.34
Skip frequency band 3
0 ~ 5.0Hz
RW
Uni
0.5
B
1.35
Reference in skip frequency band indicator
0 or 1
RO
Bit
P
L2
1.36
Analog reference 1
±
1000Hz*
RO
Bi
L2
1.37
Analog reference 2
±
1000Hz*
RO
Bi
L2
1.38~
1.40
Not used
1.41
Analog reference 2 select
0 or 1
RO
Bit
L2
1.42
Preset reference select
0 or 1
RO
Bit
L2
1.43
Keypad reference select
0 or 1
RO
Bit
L2
1.44
Precision reference select
0 or 1
RO
Bit
L2
1.45
Preset select bit 0
0 or 1
RO
Bit
L2
1.46
Preset select bit 1
0 or 1
RO
Bit
L2
1.47
Preset select bit 2
0 or 1
RO
Bit
L2
1.48
Not used
1.49
Reference selected indicator
1 ~ 5
RO
Uni
P
L2
1.50
Preset selected indicator
1 ~ 8
RO
Uni
P
L2
1.51
Power up keypad reference
0 ~ 2
RW
Uni
Txt
0
I
Содержание COMMANDER SE
Страница 76: ...76 Commander SE Advanced User Guide Issue Number 4...
Страница 93: ...Commander SE Advanced User Guide 93 Issue Number 4...
Страница 98: ...98 Commander SE Advanced User Guide Issue Number 4...
Страница 142: ...142 Commander SE Advanced User Guide Issue Number 4 Figure 6 9 Input line reactor 4400 0241 All dimensions in mm...
Страница 144: ...144 Commander SE Advanced User Guide Issue Number 4 Figure 7 3 Commander SE Size 4 All dimensions in mm...