3 608 878 300
Tightening Technology |
Bosch Rexroth AG 419
System 350
| 3 608 878 300/2019-03
MID 0503
Cancel Output signal change
MID 0504
Value change input signals
MID 0504 revision 001
Sent by:
superordinate computer
The subscription of the changes in the output signals (Logon change in the output signals,
) is reset.
Note: -
Revision:
001 (supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field:
is empty, 0 bytes
Possible response
MID
Error no. Comment
Command accepted
0005
–
Command error
0004
87
Activation for output signal change not available
Sent by:
superordinate computer
Using this message, the values of the 16 configurable input signals of the PLC-module "OpenProtocol" may be
changed.
Note: -
Revision:
(supported by Rexroth OP and Rexroth OP-Ford) and Rexroth OP-BMW)
Data field:
Number of signals, 16 bytes
Possible response
MID
Error no. Comment
Command accepted
0005
–
Table 6–116:
MID 0504 revision 001
Parameter
Comments
Bytes
Signals
Every available input signal can be applied on the OP module in the PLC
assignment table (OP 2.1 - 4.0).
ID
none
Value range
0 (not active) or 1 (active)
Presetting
-
Example:
Signals
The signals can be assigned as desired.
Value
0010010000000001, with:
– AppIn0 = 0
– AppIn1 = 0
– AppIn3 = 1
– AppIn4 = 0
– AppIn6 = 0
– AppIn7 = 1
– AppIn8 = 0
– AppIn9 = 0
– AppIn10 = 0
– AppIn12 = 0
– AppIn13 = 0
– AppIn15 = 0
– CntRes = 0
– DisRp = 0
– ResF = 0
– ResRs = 1
16
Data length revision 001
16
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...