CntSel0-7
Counter Select Bit 0-7: Selects the counter value
Input signal used for:
•
Tightening channel (
CntSel
)
•
Communication unit in single-channel operation (
CH x.y CntSel
)
These signals are used to select the OK/NOK counters. This selection takes effect irrespective of the
tightening program, e.g. by the partner controller. If a new counter value is selected before the default
value for the OK/NOK counter is reached, the channel is disabled (optional) and evaluated with
CntNOK
= "high".
Disable
Disables the application block
This signal is available as of version V2.300 of the
Rexroth Tightening System 350
.
Input signal used for:
•
Communication unit in application operation (
FO x Disable
)
When the
Disable
signal is set to "high", the corresponding application block is disabled.
DisRp
Disable Report: Suppresses the results output
Input signal used for:
•
Tightening channel (
DisRp
)
•
Communication unit in single-channel operation (
CH x.y DisRp
)
•
Communication unit in application operation (
FO x DisRp
)
When the
DisRp
signal is "high", the results output (e.g. printer output) can be suppressed for the
subsequent tightening program or the subsequent tightening application. Suppression does not apply to
outputs within the scope of BS350 and error transmission via HTTP.
DisRpFtp
Disable Report Ftp: Suppresses the results output via FTP
Input signal used for:
•
Tightening channel (
DisRpFtp
)
•
Communication unit in application operation (
KE x DisRpFtp
)
The FTP results output can also be suppressed by the PLC using the
DisRpFtp
PLC signal (signal
DisRpFtp
= "high"). This avoids having to wait for the results output when restarting. This function is
particularly useful when several tightening programs or tightening applications are started in a row.
En
Enable: Enables
Input signal used for:
•
Tightening channel (
En
)
•
Communication unit in single-channel operation (
CH x.y En
)
•
Communication unit in application operation (
FC En
)
If set to "high", the
En
signal acts as an enable signal for starting the nutrunner or all application blocks
(FO 1 ... FO 8) in a tightening cell. If the
En
signal changes to "low" while a tightening process or a
tightening sequence is in progress, the process or sequence is aborted and the tightening program or
the tightening application is evaluated to be NOK.
EnScan
Enable scanner: Enables the scanner
Input signal used for:
•
Tightening channel (
EnScan
)
•
Communication unit in single-channel operation (
CH x.y EnScan
)
This signal enables the scanner within the ErgoSpin hand-held nutrunner for the duration set within the
operating system (1) or locks this scanner (0).
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...