3 608 878 300
Tightening Technology |
Bosch Rexroth AG 611
System 350
| 3 608 878 300/2019-03
7.7
Saved ("automatic") channel configuration
The online-configuration of the tightening channel is implemented semi-automatically, i.e. all components
with electronic nameplate are configured and parameterized automatically. Mechanical components are
not equipped with such an electronic nameplate. However, in the BS350, these components have to be
configured and parameterized manually. Furthermore, manual re-configuration of the tightening channel
is also required after the tightening spindle or the
ErgoSpin
hand-held nutrunner has been replaced.
The saved ("automatic") channel configuration eliminates the manual re-configuration step upon
nutrunner replacement. This function works as follows: Upon initial online- or offline configuration of the
tightening channel, the configuration files are saved directly to the hand-held nutrunner
•
For a tightening channel with
ErgoSpin
hand-held nutrunner,
•
directly to the extension memory of the initial measurement transducer of the tightening channel for
a tightening channel with tightening
spindle. This way, a complete hand-held nutrunner respectively spindle configuration can be stored.
Previously saved configurations are overwritten.
When loading the saved configuration, the channel configuration is calculated automatically,
e.g.maximum spindle torque or maximum speed.
Saved ("automatic")
channel configuration
For tightening spindles, the following prerequisites have to be met to be able to save a created channel
configuration:
The measurement transducer 1 is of the
DMC
type.
The value of the
Channel configuration
option is "
Automatic
".
Proceed as follows to send the configuration data to the tightening controller and the tightening spindle:
Initiate saving the configuration data via
Data
Send to ...
or .
When the spindle configuration is sent, it is additionally saved to the DMC. In this, an old
configuration will be overwritten.
Loading channel
configuration
The following is required for reading in the saved configuration:
The value of the
Channel configuration
option is "
Automatic
".
The hand-held nutrunner is detected automatically and the data are imported into the tightening channel
configuration. With a Varioline hand-held nutrunner, a configuration has to be stored to the device once.
Then, it is detected automatically, too. No further user intervention is required.
With tightening spindles, the tightening controller first tries using a configuration saved to the DMC. This
means that the tightening controller reads the saved configuration when a tightening spindle with saved
channel configuration is used. The read configuration is compared to the electronic tightening
components detected (e.g. measurement transducer).
•
If the saved spindle components and the spindle components detected are identical, the saved
configuration is accepted automatically. There is no need for manual reconfiguration with the
BS350
operating system.
•
If the saved tightening channel configuration and the spindle components detected automatically
differ, the channel has to be re-configured in the operating system
BS350
and the data have to be
sent to the controller.
This function is supported as of version V2.200 of the
Rexroth Tightening System 350
.
If there are two measurement transducers, the configuration is saved to the transducer that is only
connected to one CAN line (MC1).
Other measurement transducers are not supported for this function. There will be no error messages
either.
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...