148
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
This signal indicates that the job was evaluated with NOK.
Job Ok
Job OK: The job result is okay
This signal is available in the compact system as of version V2.300, KE as of V2.400 and SE as of
V2.500 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel: Compact system (
Job OK
)
•
Communication unit in single-channel operation (
CH x.y Job OK
)
•
Communication unit in application operation (
KE Job OK
)
This signal indicates that the job was evaluated with OK.
Job Rdy
Job ready: The job is ready
This signal is available in the compact system as of version V2.300, KE as of V2.400 and SE as of
V2.500 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel: Compact system (
Job Rdy
)
•
Communication unit in single-channel operation (
CH x.y Job Rdy
)
•
Communication unit in application operation (
KE Job Rdy
)
A job for a controller cannot be started before the system indicates that it is "ready" with the
JobRdy
signal (signal
JobRdy
= "high").
Job InCy
The job is active
This signal is available in the compact system as of version V2.300, KE as of V2.400 and SE as of
V2.500 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel: Compact system (
Job InCy
)
•
Communication unit in single-channel operation (
CH x.y Job InCy
)
•
Communication unit in application operation (
KE Job InCy
)
This signal reports the start of a job to a partner controller. It is of particular importance for hand-held
tightening systems.
If the
Job InCy
is "high", the
Job CyCmp
,
JobOK
and
JobNOK
signals are set to "low". Once the job
sequence (
Job CyCmp
= "high",
Job Start
start signal "low") is exited, the
Job InCy
signal drops to "low".
JobOut 0-31
Job Out Bit 0-31: Job-specific output signal
This signal is available in the compact system as of version V2.300, KE as of V2.400 and SE as of
V2.500 of the
Rexroth Tightening System 350
.
Output signal used for:
•
Tightening channel: Compact system (
JobOut0-31
)
•
Communication unit in single-channel operation (
CH x.y JobOut0-31
)
•
Communication unit in application operation (
KE JobOut0-31
)
Using these signals, states within the job can be reported to superior controllers.
KE ILOut
Kommunikationssystem Indra Logic Out Bit 0-7: IL-specific output signal
Output signal used for:
•
Communication unit in application operation (
KE ILOut x.0-7
)
IL-specific signals are provided for special adjustments to customer requirements. They are, e.g., suitable
for looping through signals: a signal can be read by the controller via interface modules and then output
to the partner controller using the controller.
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...