3 608 878 300
Tightening Technology |
Bosch Rexroth AG 217
System 350
| 3 608 878 300/2019-03
Proceed as follows to install a CF350 memory module:
1.
De-energize the compact system or modular system.
2.
Insert the CF350 memory module into the slot labeled "X6C1".
The new memory module will be automatically recognized.
3.
Check the contents of the CF350 storage module in the BS350 operating system under
Systemtest
, and format the CF350 storage module, if necessary.
Fig. 6–7:
Example of data exchange via FTP with CS351 and two separate control units
NOTICE
Stable operation endangered
Inserting or removing the memory module during operation can impede access to the controller;
further errors and error messages may result.
First, ensure that the tightening system is switched off and de-energized.
Only then, insert the CF350 memory module into slot X6C1 or remove the memory module from
the slot.
1)
1)
vor Ablaufende (Cy Cmp)
2)
nach Ablaufende (Cy Cmp)
Schraubergebnisse
2)
ID-Codes
Control unit 1/FTP server
Tightenin
g results
storage
FTP
client
FTP
server
Control unit 2
Ethernet (TCP/IP)
CS351
FTP
client
FTP
server
Tightening
controller
CF350
ID codes
Data buffer
Before sequence end (Cy Cmp)
After sequence end (Cy Cmp)
Tightening results
ID codes
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...