3 608 878 300
Tightening Technology |
Bosch Rexroth AG 529
System 350
| 3 608 878 300/2019-03
To connect the ErgoSpin hand-held nutrunner:
1.
Insert the ErgoSpin connection cable in the plug on the handle of the hand-held nutrunner (use the
guide grooves and catches) and tighten the union nut firmly by hand.
2.
Insert the connection cable plug as follows:
– on the compact system (CS) into the XDS1 interface
– on the LTU350/1 in theXDS1 interface
– on the LTE350D in theXDS1 interface
3.
Align the angle plug with the compact system respectively with the servo amplifier in the desired
outlet direction.
4.
Secure the plug at the compact system or the servo amplifier by fully tightening the union nut.
7.2.6.3
CS351 compact system mains connection
The compact system is delivered with an EU mains connection and mains connection plug with screw
terminals. The mains connection cable can be unscrewed at the connection plug and assembled as
desired.
The mains connection interface (X1N) is located outside the front cover (see Figure
Fig. 7–4:
X1N mains connection interface on the compact system
Always use angle plugs on the servo amplifier with the system box (SB) so the system box door can be
closed.
NOTICE
Use of non-original parts
Damages to the compact system
Only use mains connection cables from Bosch Rexroth.
You can find suitable cables in Bosch Rexroth's delivery program. Please also observe the local
regulations.
XDS1
QO
X1N
CS351E-D
CS351S-D
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...