3 608 878 300
Tightening Technology |
Bosch Rexroth AG 555
System 350
| 3 608 878 300/2019-03
Channel
configuration of open
flat output drives
BS350 allows for simple configuration of the ErgoSpin hand-held nutrunner with open flat output drives.
Using the
Flat output drive (F)
parameter dialog (the symbol is shown in Figure
) select the output
drive spin direction and reverse spin direction. Depending on these two settings, the alignment spin
direction of the motor is adjusted accordingly. In this way, you can use flat output drives with
counterclockwise
spin direction and flat output drives with
clockwise
spin direction.
"Referencing
Fig. 7–18:
Channel configuration: Symbol flat output drive (F)
Table
describes the parameters that you can set in the
Flat output drive (F)
parameter dialog.
Table 7–13:
Parameter for setting the flat output drive (F)
Parameter
Description
Code
With flat output drives, there is no selection option. The component is displayed
with the corresponding serial number as soon as you accept the configuration.
Order number
Component order number
Serial number
Component serial number
Efficiency
Specification of efficiency in percent [%]
– Value range: 0% … 100%
Transmission
Specification of the transmission
– Value range: 0 … 1.000
Max. torque
Maximum torque up to which the flat output drive may be used
Reverse spin direction
Specification of an option for a reverse spin direction
– Activated
Select this option if the drive spin direction of the flat output drive does
not
correspond
to the output drive spin direction of the flat output drive.
–
Deactivated
Select this option if the drive spin direction of the flat output drive
corresponds
to the output drive spin direction of the flat output drive.
Output drive spin direction
Specification of the mechanically defined spin direction / tightening direction
(spin direction not running towards the safety catch) of the flat output drive
Value range:
–
Counterclockwise
–
Clockwise
Cycle counter
Cycles that have already been run through on the flat output drive.
– Presetting: 0
Open flat key program-controlled
This parameter is available for flat output drives without safety catch as of
Rexroth Tightening System V2.400.
Activate this option for configuration of the open flat output drive without safety
catch. After sending, the system is restarted.
Precise motor screw reduction
ratio
This parameter is available for flat output drives without safety catch as of
Rexroth Tightening System V2.400.
Specification of the accuracy for the reduction ratio of the motor screw. For open
position accuracy, the value should be entered with 12 decimal places. See also
table
Change component
Click on this button in case of a component change to save the serial number
and the number of cycles of the new component.
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...