330
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
6.7
Rexroth Open Protocol
This chapter describes the communication between the superior computer and tightening controller via
the Rexroth Open Protocol. During communication, the superior computer acts as a client and the
tightening controller acts as a server.
The Rexroth Open Protocol is a communication protocol based on TCP/IP that has been specially
developed for tightening controllers. Up to 5 clients connected to each other can be managed using the
Open Protocol.. Users can configure a tightening controller and get information on events in the
tightening controller via the client.
6.7.1
Settings in the BS350 operating system
The following settings can be made for the Rexroth Open Protocol in the BS350 (
System
Tightening
cell data
Open Protocol
):
The Open Protocol function is available for the compact system as of version 2.100.
The "Rexroth OP-Ford" Open Protocol is also available for the modular system as of firmware version
2.300.
In order to use the Rexroth Open Protocol, a CF350 (memory card) must be inserted in the Compact
System (CS) or the communication unit (KE).
Table 6–66:
Settings for the Rexroth Open Protocol in the BS350
Area
Element
Description
Interface
Protocol activated
The data protocol is active if this checkbox is selected.
TCP/IP port
Selection of the desired TCP/IP ports (presetting: 4545).
Protocol
Version
Data protocol selection
– Rexroth OP R1.0 (subsequently referred to as
Rexroth OP
)
– Rexroth OP-Ford R1.0 (subsequently referred to as
Rexroth
OP-Ford
)
– Rexroth OP-BMW R1.0 (subsequently referred to as
Rexroth
OP-BMW
)
1
Keep alive timeout
Indication of the time in which messages must be received. If no
message is received within this time, the connection will be
disconnected. (Presetting: 15 seconds).
Response timeout
Specification of the time within which the message acknowledging
data transfer must be sent (presetting: 2 seconds). This
information is only required for a reliable mode. This time will be set
a max. of 4 times. If an acknowledgement of data transfer fails to
be received within the 4th time span, the connection will be
disconnected.
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...