Fig. 7–39:
Switch S2
Fuses
The intermediate circuit of the servo amplifier is protected by two safety fuses. If these fuses blow (melt),
the BTB LED changes from green to red. In this state, operation is no longer possible.
These safety fuses are located on the rear of the servo amplifier and must be replaced in the case
described above (for removal, see Figure
).
Fig. 7–40:
Removal of the safety fuses
Recommended fuse: 3 608 875 374, 12 A, 500 V DC, 10,3 x 38 mm
Manufacturer: Ferraz Shawmut
Order number: 6JX12