532
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
7.2.6.5
SB356 system box mains connection
The mains connection is implemented via the screw terminals on the mains switch (see Figure
Table
).
The cable fitting (Ø 8 mm – 13 mm) is located in the system box base.
The SB356 mains connection must be 3-phase (4 x 2.5 mm
2
) and include a PE wire. To avoid short
circuits and ground leakage, a 3-phase fuse (16 A) must be provided.
Fig. 7–7:
SB356 mains connection terminals
Voltage selection
The voltage selection terminals in the SB356 allow for operating the system box in a voltage range of
380 V to 500 V.
The system box is set to 400 V at the time of delivery (see Figure
).
The X1N4 interface partitions represent a logical separation of the 3 possible connection groups (G1 to
G3) (see Figure
Table 7–4:
Description of the mains connection terminals on the SB356
Signal
Description/function
Voltage/current
PE
PE wire
PE potential
1L1
L1 mains connection
380 – 500 V~ / 4.6 – 3.5 A
3L2
L2 mains connection
380 – 500 V~ / 4.6 – 3.5 A
5L3
L3 mains connection
380 – 500 V~ / 4.6 – 3.5 A
1L1 3L2 5L3
PE
NOTICE
Damages caused by varying voltages
Varying mains voltages will damage the control and power electronics.
All three mains phases must be connected with the same voltage value!
NOTICE
Varying assignment of mains connections
Damages to the control and power electronics
Only use the voltage selection terminals from the G1, G2, and G3 groups for the mains
connection.
Do not assign the device connection.
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...