background image

USER’S MANUAL

INLINE FANS IN SOUND-INSULATED CASING 

EN  

Iso-Mix EC 

Содержание Iso-Mix EC Series

Страница 1: ...USER S MANUAL INLINE FANS IN SOUND INSULATED CASING EN Iso Mix EC ...

Страница 2: ...7 Operation guidelines 8 Designation key 8 Installation and set up 9 Connection to power mains 13 Electronics operation algorithm 14 Technical maintenance 15 Troubleshooting 16 Storage and transportation regulations 16 Manufacturer s warranty 17 ...

Страница 3: ... and practical training in the field of ventilation systems and should be able to work in accordance with workplace safety rules as well as construction norms and standards applicable in the territory of the country READ THE USER S MANUAL CAREFULLY BEFORE PROCEEDING WITH INSTALLATION WORKS COMPLIANCE WITH THE MANUAL REQUIREMENTS ENSURES RELIABLE OPERATION AND LONG SERVICE LIFE OF THE UNIT KEEP THE...

Страница 4: ...lation and maintenance The present user s manual should be carefully read before beginning works Single phase power mains must comply with the acting local electrical norms and standards Fixed electrical wiring must be equipped with an automatic circuit breaker The unit must be connected to power mains through a QF automatic circuit breaker integrated into the fixed wiring system The gap between t...

Страница 5: ...of smoke carbon monoxide and other combustion products into the room through open chimney flues or other fire protection devices Sufficient air supply must be provided for proper combustion and exhaust of gases through the chimney of fuel burning equipment to prevent back drafting Transported air must not contain any dust or other solid impurities sticky substances or fibrous materials Do not use ...

Страница 6: ...put objects on it The unit is allowed to be used by children aged from 8 years old and above and persons with reduced physical sensory or mental capabilities or no experience and knowledge provided that they have been given supervision or instruction regarding safe use of the unit and understand the risks involved Do not allow children to play with the unit ...

Страница 7: ...time The fan is designed for connection to ø 100 125 150 160 200 250 and 315 mm air ducts The fan is equipped with an energy efficient and high performance electronically commutated motor EC motor and a built in speed controller An external control unit can be connected to the fan The fan design is constantly being improved thus some models may be slightly different from those described in this ma...

Страница 8: ...ins plug FR built in smooth speed controller and power cord with mains plug Rated spigot diameter mm Motor type Fan model OPERATION GUIDELINES The fan is rated for connection to single phase AC 230 V 50 60 power mains The fan is rated for continuous operation Air motion direction in the system must match the pointer on the fan casing Hazardous parts access and water ingress protection rating is IP...

Страница 9: ...mounting on the floor on the wall or on the ceiling While mounting the fan provide extra protection against water ingress such as For the top mounting install an outer protecting hood above In case of any mounting position connect an air duct on both sides of the fan 4 x D 4 x D ...

Страница 10: ...n turned off Mark the holes for fixing the fan and the power cable Lead the power cable to the ventilation hole drill the mounting holes and install the dowels Fix the fan with the screws For any mounting position connect an air duct on both sides of the fan ...

Страница 11: ...an cover Installation locations of the R1 potentiometer XP1 and XP2 terminals are shown on the control board DIP switch SW Х1 Х2 R1 SW Connect the XP1 and XP2 terminal block counterparts Reassemble the fan in the reverse order Supply power to the fan S1 ...

Страница 12: ...12 Features of different fan models control Iso Mix EC XXX G Iso Mix EC XXX GI Iso Mix EC XXX FR Thermostat control knob Speed control knob Speed control knob ...

Страница 13: ...30 V 50 60 Hz power mains GND general Х2 terminal block for connection of an external speed controller TACH 2 signals per 1 revolution S1 external speed controller 0 10 V SW DIP switch QF external circuit breaker R1 internal speed controller N L QF 2 SW R1 X1 X2 blue red yellow blue white brown external control device 230 V 50 60 Hz DO NOT USE A METAL SCREWDRIVER KNIFE ETC FOR ADJUSTMENT OPERATION...

Страница 14: ...XXX G Iso Mix EC XXX GI fans is equipped with an electronic module speed controller with an electronic thermostat for automatic motor speed control air flow depending on the air temperature The terminal compartment incorporates 2 control knobs motor speed preset button electric thermostat control knob The LED indicator is placed at the front panel of the fan to show the thermostat operating status...

Страница 15: ... power supply and make sure electricity has been turned off Disconnect the air duct on both sides of the fan Clean the fan with a soft dry cloth or a brush Wipe the fan surfaces dry Connect an air duct on both sides of the fan Supply power to the fan CAUTION Do not allow water or liquid come into contact with electric components ...

Страница 16: ...orted only in the working position Avoid sharp blows scratches or rough handling during loading and unloading Prior to the initial power up after transportation at low temperatures allow the unit to warm up at operating temperature for at least 3 4 hours TROUBLESHOOTING Problem Possible reasons Troubleshooting When the unit is connected to power mains the fan does not rotate and does not respond t...

Страница 17: ...air includes work specific to elimination of faults in the unit operation to ensure its intended use by the user within the guaranteed period of operation The faults are eliminated by means of replacement or repair of the unit components or a specific part of such unit component The warranty repair does not include routine technical maintenance unit installation dismantling unit setup To benefit f...

Страница 18: ... unit warranty period Violation of the unit transportation regulations by the user Violation of the unit storage regulations by the user Wrongful actions against the unit committed by third parties Unit breakdown due to circumstances of insuperable force fire flood earthquake war hostilities of any kind blockades Missing seals if provided by the user s manual Failure to submit the user s manual wi...

Страница 19: ...19 Quality Inspector s Stamp Sold by name and stamp of the seller Manufacture Date Purchase Date ...

Страница 20: ...blaubergventilatoren de B97 1EN 04 Iso Mix EC 100 125 150 G 160 GI 200 FR 250 315 ...

Отзывы: