Technical Documentation
VeriSens
®
v2.11.0-B4
83/429
Baumer Optronic GmbH
Radeberg, Germany
Example
Setting an expected value for the
Text
feature check via the process interface and determining the required
command.
NOTE
The preview window on the right shows you in real time how your settings affect the data
to be sent.
1.
Configure the
Text
feature check.
2.
Go to the
Configure interface → Input process interface
step.
3.
Configure all of the settings in the overview for the data input (see Data table
settings).
(1) Select the feature check / setting to be set.
(2) Select the value to be output.
(3) Set the start character, separator and end character for the datagram.
4.
You will now see the current set
value in the preview window on the
right. The SP (Set Parameter) and
the number of characters (4 byte
ASCII-Hex) will also be prefixed
(see SP command)
<Start>17.03.2014<End>
NOTE
If no value is set as "expected" during
configuration of the feature check, no value
will be shown in the preview window!
5.
The command to set the expected
value for the device to this date is
therefore:
SP0017<Start>17.03.2014<End>
(Note: 0017
HEX
= 23
DEZ
, length is therefore 23 characters)