15.5.5 EtherNet/IP
TM
15.5.5.1 LEDs on the Vision Sensor
LED
Meaning
LINK / ACT
Indicates that the Vision Sensor is connected to a network.
On: Network connection established
Blinking: Data traffic active
NET RUN
Indicates that data is being transferred via Ethernet/IP.
Off: Ethernet/IP will not be used
Long blinking: Waiting for first cyclical connection
On: Cyclical connection active
Short blinking: Cyclical connection ended (waiting for next connection)
15.5.5.2 Cabling
Follow the general rules for cabling Industrial Ethernet.
Use a shielded cable for data transfer. The maximum cable length is 100m. Make sure during cable
assembly that the cable shield is properly connected with the connector housing.