Technical Documentation
VeriSens
®
v2.11.0-B4
424/429
Baumer Optronic GmbH
Radeberg, Germany
19.9 Technical data
General data
XC series
XF series | CS series | ID series
Resolution
640 × 480 px 1280 × 960 px
1600 × 1200 px
752 × 480 px
Sensor
(monochrome)
1/4" CCD
(monochrom
e, colour)
1/3" CCD
(monochrome,
colour)
1/1.8" CCD
(monochrome)
1/3" CMOS (monochrome, colour)
LED illumination
Fully integrated flash controller for external illumination White (LED class: Risk group 1 low
risk, EN 62471:2008)
Infra-red (LED class: free group risk
free, EN 62471:2008) (860 nm)
Lens
Replacement lens (C-mount)
f = 8
mm
f = 10
mm
f = 12
mm
f = 16
mm
Min. object distance
Depending on changeable lens
50 mm
50 mm
50 mm
70 mm /
100 mm
1)
Max. object distance
Depending on changeable lens
450 mm
∞
450 mm
300 mm
Speed
Full resolution
Reduced, max.
speed (reduced
resolution,
monochrome)
Max. Insp / s
50 | 116
1
)
100 | 144
1
)
Max. Insp / s
12 | 31
1
)
25 | 54
1
)
Max. Insp / s
7 | 21
1
)
15 | 35
1
)
Max. Insp / s
50
100 (monochrome, only XF series)
Reduced, max. brightness,
(monochrome, XF series only)
Defect image
memory
32
8
4
32
Number of jobs
Up to 255 on the device (can be exchanged via process interface)
Features per job
32
Electrical data
XC series
XF series | CS series | ID series
Nominal voltage
power supply
So
c
k
e
t
2
24 V ± 25% / Class 2 according to NEC / protection class III
The device is intended for supply from an isolated limited power source according to UL61010-1,
3rd ed cl. 9.4 or a limited energy source according to UL60950-1 or Class 2 according to NEC.
Power
consumption
max. 42 W (with I/O and lighting)
max. 18 W (with I/O)
Inputs
8 ... 30 V (polarity protected)
Outputs
PNP I
peak
= 100 mA and I
eff
= 50 mA (short-circuit
proof)
Digital input
Trigger, Job selection, External teach, Encoders (CH-A, CH-B) 500 kHz
Digital output
Pass / Fail 1-5
2
), flash sync, alarm, image trigger permitted, result valid
Communication
initial set-up
Process interface
So
c
k
e
t
1
Ethernet (10BASE-T / 100BASE-TX)
PROFINET (CC-A)
1)
/ Ethernet/IP™
1)
, TCP / UDP (Ethernet)
3)
So
c
k
e
t
2
RS485
4)
1)
only XC700 / XC800 / XC900 and ID510
2)
ID100: 1-3
3
) except CS100
4)
only
ID100