Technical Documentation
VeriSens
®
v2.11.0-B4
105/429
Baumer Optronic GmbH
Radeberg, Germany
10.2.5 Digital I/Os
You can adjust the settings for the digital interface on this dialogue page. You can also configure an
incremental encoder and specify the polarity of the digital inputs and outputs.
Inputs
Input 1 is reserved for the trigger. For other inputs you can specify how you want to switch the active job. It is
also possible to connect an incremental encoder to the Inputs 5 (CH-A) and 4 (CH-B).
Outputs
NOTE
The number of configurable outputs is device dependant.
Enter how the outputs are to be activated here. Hardware signals (image trigger permitted, result valid,
result, alarm, flash sync, device activated, heat warning, heat shutdown) can be issued for each output or the
output configured for issuing job results.