![Baumer VeriSens CS Series Скачать руководство пользователя страница 157](http://html.mh-extra.com/html/baumer/verisens-cs-series/verisens-cs-series_technical-documentation-manual_2710941157.webp)
Technical Documentation
VeriSens
®
v2.11.0-B4
157/429
Baumer Optronic GmbH
Radeberg, Germany
If the feature check is to be corrected by the result of the part location, you can choose this option
here. The location of the detection area will be refreshed when this is activated. External teach also
makes it possible to retrain the feature check. Select the appropriate option for this purpose.
Confirm your settings and return to the feature list with
OK
. Return to the feature list without making
any changes with
Cancel
.
This feature check has the following output values for the datagram at the process interface:
Output value
Data type
Description
Result
Result of the feature check: "P" (Pass); "F" (Fail)
Conformity
Integer
Match of the model (%)
Centre of object
Float point
Position of the object in the image (px)
Angle of object’s
rotation
Float
Angle of the object (degrees)