Technical Documentation
VeriSens
®
v2.11.0-B4
308/429
Baumer Optronic GmbH
Radeberg, Germany
15.4.3 Command GA
– temperature alarm queries
This function enables you to query the device's current temperature status.
An internal protection device intervenes when the device is operated outside of specification; this is intended
to protect the components against destruction by heat.
The
Application Suite
, the web-interface and the process interfaces will output an overheating warning to
notify users that the maximum permissible operating temperature has been reached (circa 85
–90% of
loading, see the
Request GT heat state command
).
Should the housing temperature continue to rise, the device will undergo emergency shutdown to protect it
from damage.
Example
Structure of the command
PLC
device
Command
Parameters
G
A
G
et
A
larm
none
Structure of the Response
PLC
device
Response
R
A
0
0
0
0
0
0
0
0
R
esponse
A
larm
8 byte ASCII hex
Temperature status
Parameters of the "RA" command
– current temperature status
The current temperature status will be transmitted using 8 characters, where the first 7 characters in a bit
mask are always 0 and the current temperature status is contained in bits 0 and 1 of the eighth character.
Bits
3
2
1
0
3
2
1
0
1. ASCII characters
2. ASCII characters
0
0
3. ASCII characters
4. ASCII characters
0
0
5. ASCII characters
6. ASCII characters
0
0
7. ASCII characters
8. ASCII characters
0
0
Thermal
shutdown
Heat
warning