Technical Documentation
VeriSens
®
v2.11.0-B4
379/429
Baumer Optronic GmbH
Radeberg, Germany
The following tables describe the mapping of data elements in memory.
Input data (device
PLC)
target (T) to (originator (O), assembly instances 110):
Byte
Group
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Alarms
Alarms
pad (0)
1
pad (0)
2
pad (0)
3
pad (0)
Thermal
shutdown
Heat
warning
Hand
-
shake
error
Pipeline
overflow
Buffer
overflow
4
Control and
status
Device status
pad (0)
Img Proc
ACT
Operating Mode
Teach
ACT
TRG
RDY
5
Current job
number
Active job number
6
Thermal state
Thermal state
7
Action status
pad (0)
Status SM
Status SP
Status SJ
8
Job results
pad (0)
Alarm
Total
Res Fail
Total
Res
Pass
9
pad (0)
10
Sub Res 4
Fail
Sub
Res 4
Pass
Sub
Res 3
Fail
Sub Res
3 Pass
Sub Res
4 Fail
Sub
Res 4
Pass
Sub Res
3 Fail
Sub Res
3 Pass
11
pad (0)
Sub Res
5 Fail
Sub Res
5 Pass
12
Device alarms
Alarm
PIF
Pipe OV
Alarm
PIF
Buf
OV
Alarm
FTP
Alarm
PIF
Alarm
Inv Job
Alarm
Output
Timeout
Alarm
Inv TRG
Alarm
(Any)
13
Alarm
PIF
HS Err
14
pad (0)
15
pad (0)
16
Handshake for
output data
pad (0)
O -> T
HS
ACK
pad (0)
O -> T
HSWA
ACT
ACK
O -> T
HSS
ACT
ACK
17
Handshake for
input data
pad (0)
T -> O
HS
Flag
pad (0)
T -> O
HSWA
ACT
ACK
T -> O
HSS
ACT
ACK
18
Result data
Actual
Length
Result data
19
…
146
Result data
Result data (128 byte)
147
Handshake for
input data
pad (0)
T -> O
HS
Flag
pad (0)
T -> O
HSWA
ACT
ACK
T -> O
HSS
ACT
ACK
148
Parameters
Handshake for
output data
pad (0)
O -> T
HS
ACK
pad (0)
O -> T
HSWA
ACT
ACK
O -> T
HSS
ACT
ACK
149
Trigger data
Handshake for
output data
pad (0)
O -> T
HS
ACK
pad (0)
O -> T
HSWA
ACT
ACK
O -> T
HSS
ACT
ACK