Technical Documentation
VeriSens
®
v2.11.0-B4
74/429
Baumer Optronic GmbH
Radeberg, Germany
9.3.3 Output Robotics (device dependent)
In this dialogue, you can configure the data outputs for the Robotics.
NOTE
You can configure the activation of this interface in the
Device settings
.
Device
Device settings
Robotics
Waypoint feature:
Select the feature check for the waypoints of the robot. The first robot-compatible feature
check that has been configured is entered automatically. If no robot-compatible feature check is selected,
then no waypoint coordinates determined by the image processing can be used.
NOTE
To be able to select a feature check on
Feature by Waypoint
, the
distortion correction
and
Z calibration
must be configured. Furthermore,
Convert image coordinates to world
coordinates
must be activated.
With the
+
and
–
buttons, you may add a new line or erase the currently selected line, respectively. Each
line contains one feature to be transferred.