Binary switching point:
Set the binary switching point at a value between 0 and 255.
Colour:
This is where you enter the phenomenon that differentiates the objects to be counted from
their surroundings.
Exclude cropped areas:
Areas which touch the edge of the field of view are excluded from the
analysis.
Areas filter:
Adjust the minimum and maximum number of pixels of the counted areas. You can
invert the result using the right button.
If the feature check is to be corrected by the result of the part location, you can choose this option
here. External teach also makes it possible to retrain the feature check. Select the appropriate option
for this purpose.
In order to be independent of fluctuations in the ambient light, the device offers a means of automatically
correcting the brightness.
The mean brightness in the field of view of the reference area should exceed a grey scale value of 128 to
ensure reliable operation.
Use, do not carry reference area:
Here, a field of view is defined as a reference area, for example
by attaching a white label to the edge of the conveyor belt (static). The brightness correction is now
guided by the brightness of this area.
Use, carry reference area:
This function is only available in connection with part location. A field of
view is still used as the reference area. However, this is carried with the position correction. The
brightness correction is now guided by the brightness of this carried area.