15.5.4.5.5
Example
The following examples provide a depiction of the mapping of data elements in memory for two module
configurations.
Number
Description
1
PLC
2
PLC programme
3
PLC process map
Example 1
Simple configuration
– use of the "Control and status" and "Result data (32 bytes)" modules with
selected start address 1000 / 500 (start addresses subject to overall configuration).
Vision Sensor input data
device
PLC
Control and status
Result data
Start address:
1000
Start address
+ 13
Start address
+ 14
Start address
+ 48
Vision Sensor output data
PLC
device
Control and status
Result data
Start address:
500
Start address
+ 5
Start address
+ 6
Example 2
Extensive configuration
– use of the "Control and status", "Result data (250 byte)", "Parameters (128
byte)" and "Trigger data (64 byte)" modules with selected start address 200 / 100 (start addresses
subject to overall configuration).
Vision Sensor input data
PLC
device
Control and status
Result data
Parameters
Trigger data
Start address:
200
Start address
+ 13
Start address
+ 14
Start address
+ 252
Start address
+ 253
Start address
+ 254
Vision Sensor output data
device
PLC
Control and status
Result data
Parameters
Trigger data
Start address:
100
Start address
+ 5
Start address
+ 6
Start address
+ 7
Start address
+ 137
Start
address
+ 138
Start
address
+ 203
4
Device