Data table settings
The following items are selected in the table:
Column
Meaning
Active
If this entry is marked, the desired value is entered in the datagram.
Feature
The setting or the feature check from which a value is to be transferred is selected here.
Value
The result of the feature check that is to be transferred is selected here. The results depend
on the relevant feature check.
Start
This character string prefixes the result to be transferred and can make it easier for the
receiver to interpret or make the data packet readable for human users.
Format
The format used to represent the data to be transferred is set here. The options provided
depend in principal on the values available. Customarily, the following possible options are
offered:
ASCII (2 decimal places)
ASCII (Exponent)
Decimal
Binary (Little Endian)
Binary (Big Endian)
NOTE
This means that the data packet can contain characters that
are normally used as control characters for serial interfaces
or in the protocol. This setting is only recommended if the
operating conditions are appropriately secured!
Fixed
length
The length of the expected values is adjusted here. Missing characters are filled with zeros
(numbers) or spaces (text).
NOTE
Following the descriptions of the individual feature checks, there is a table containing the
values which can be input via the process interface.