Technical Documentation
VeriSens
®
v2.11.0-B4
55/429
Baumer Optronic GmbH
Radeberg, Germany
6.
Set the target parameters. Assign coordinates to the reference point. Determine the units for the grid.
7.
Determine the orientation for the coordinate system (left-handed / right-handed).
NOTE
The overlaid coordinate system only specifies the orientations (X,Y) and does not
necessarily show the zero point!
8.
Determine a main orientation for the coordinate system. These orientations will be aligned to the
target grid. Rotation is thus only possible in steps of 90°.
9.
Press the
Transfer to device button.
The programmed coordinates will be transferred to the Vision Sensor.
NOTE
A reference point cannot be moved once it has been programmed. Renewed teaching is
required to determine a new reference point.