Technical Documentation
VeriSens
®
v2.11.0-B4
340/429
Baumer Optronic GmbH
Radeberg, Germany
Data element
Direction
Type
Length
(byte)
Description
Device status
Device
PLC
UINT8
1
Status word, corresponds with the "GS" process
interface command
Bit 0
TRG ready
0: Trigger not permitted,
1: Trigger permitted
Bit 1
Teach
0: Teach will not be carried out with
the next image recorded
1: Teach will be carried out with the
next image recorded
Bits 2..3
Mode
0: Run mode
1: Configuration mode
2: Test mode
Bit 4
ImgProcAct
0: Image acquisition/analysis not
active
1: Image acquisition/analysis active
Bits 5..7:
Reserved (always 0)
Current job
number
Device
PLC
UINT8
1
Current job number 1..255
0: if not in run mode or if job switching is active,
corresponds with the "GS" process interface
command
Thermal state
Device
PLC
UINT8
1
The device's current thermal state (capacity in
percent), corresponds to the "GT" process interface
command
Action status
Device
PLC
UINT8
1
Status for various actions, corresponds with the
"GS" process interface command
Bits 0..1
Job switching status
0: idle (no request pending),
1: in progress
2: completed successfully
3: completed with errors
Bits 2..3
SetParam status
0: idle (no request pending)
1: in progress
2: completed successfully
3: completed with errors
Bits 4..5
SwitchMode status
0: idle (no request pending),
1: in progress
2: completed successfully
3: completed with errors
Bit 6..7
Reserved (always 0)