Technical Documentation
VeriSens
®
v2.11.0-B4
57/429
Baumer Optronic GmbH
Radeberg, Germany
SmartGrid
1.
Place the
SmartGrid
with world coordinate system orientation into the Vision Sensor's field of view.
2.
Press the
Edit button
.
3.
Select the
SmartGrid
method.
4.
Press the
Teach
button.
The grid points will be programmed and marked with a small orange cross. Furthermore, a
representative reference point is inserted and the alignment is determined according to
SmartGrid
.
The reference point can optionally be moved by mouse, the corresponding coordinates are displayed
in the greyed out Reference Point field.
NOTE
Should this teaching fail, a user defined coordinate system could be programmed.
Causes could be:
-
The SmartGrid squares are too small (minimum size 20 x 20 pixels)
-
There are too few squares in the field of view (at least 6 x 8 related squares are
required, preferably more)
NOTE
The overlaid coordinate system only specifies the orientations (X,Y) and does not
necessarily show the zero point!
5.
Press the
Transfer to device button.
The programmed coordinates will be transferred to the Vision Sensor.