Technical Documentation
VeriSens
®
v2.11.0-B4
415/429
Baumer Optronic GmbH
Radeberg, Germany
18 Excess temperature behaviour (only devices with integral Industrial
Ethernet)
An internal protection device intervenes when the device is operated outside of specification; this is intended
to protect the components against destruction by heat.
The
Application Suite
, the web-interface and the process interfaces will output an overheating warning
message. This notifies the user that the maximum permissible operating temperature has been reached prior
to the device undergoing emergency shutdown.
Warning message
Subject to temperature situation, work can be briefly continued at
this warning level; to save the project, for example.
Confirm the query to do this.
Emergency shutdown
Should the housing temperature continue to rise, the device will
undergo emergency shutdown to protect it from damage.
After cooling, the supply voltage must be briefly interrupted and
restored to be able to use the device again after shutdown.
A further warning message will provide information about the
previous emergency shutdown of the device.