Technical Documentation
VeriSens
®
v2.11.0-B4
425/429
Baumer Optronic GmbH
Radeberg, Germany
Integr. Flash
controller
XC series
XF series | CS series | ID series
Voltage
(permanent)
Voltage (pulsed)
So
c
k
e
t
3
12 VDC or
24 VDC
24 VDC or
48 VDC
–
Current
(permanent)
Current (pulsed)
I
max
= 800 mA at
24 VDC
(+/-10 %, at least +/- 100 mA, at 25 °C)
I
max
= 4 A at
48 VDC
(+10/-20 %, at least +/- 100 mA, at 25 °C)
–
Flash time
Max. 1 ms (Duty Cycle max. 1:10)
–
Operating
conditions
XC series
XF series | CS series | ID series
Operating
temperature
Operating temperature: +5 … +55 °C @ measuring
point
Operating temperature: +5 … +60 °C
@ measuring point
Storage temperature
-
20 … +70 °C
Humidity
0 … 90 % (non-condensing)
Protection class
IP 67 (XC-Series: with tube)
IP 67, IP 69K (device dependent)
Vibration load
IEC 60068-2-6, IEC 60068-2-64
Mech. shock
resistance
EN 60068-2-27
Mechanical data
XC series
XF series (XF series in IP 69K) | CS
series | ID series
Width × Height ×
Depth
53 mm × 99.5 mm × 49.8 mm (without lens / tube)
53 mm × 99,5 mm (IP 69K: 107,5 mm)
× 38 mm
Material
Housing: Aluminium, cover glass tube: PMMA
Housing: Aluminium (IP 69K:
Stainless
steel 1.4404) Cover glass:
PMMA
5
)
Weight
300 g (without lens / tube)
250 g (IP69K 700 g)
Code types / OCR
Model: XC800 / XC200
Models: XF200 / XF800 / XF205 |
ID110 | ID100
Barcode
6)
2/5 Industrial, 2/5 Interleaved, Codabar, Code 39, Code 93, Code 128, PharmaCode
EAN 8, EAN 13, UPC-A, UPC-E: Base code + versions Add-On 2, Add-On 5
GS1 DataBar (RSS): Limited, Expanded, Expanded Stacked
GS1 DataBar (RSS-14): Base code + versions Truncated, Stacked, Stacked Omnidir
GS1 128
Matrix code
6
)
DataMatrix (ECC 200), GS1-DataMatrix, QR, PDF417
Font
7)
Optional fonts (recommended: sans serif, proportional), dot matrix, characters: A-Z a-z 0-9 + -. : /
( )
5)
for XF700 / XF105 / XF100 / XF800 / XF205 / CS100 / ID110 / ID510 with infra-red illumination:
780 nm
daylight filter built-in
6
) incl. quality rating of all barcodes according to ISO / IEC 15416 as well as all matrix codes according to
ISO / IEC 15415 or AIM DPM-1-2006
7)
only XC800 / XC900 / XC200 / XF800 / XF900 / XF205 / ID110 / ID510