Technical Documentation
VeriSens
®
v2.11.0-B4
154/429
Baumer Optronic GmbH
Radeberg, Germany
12 Feature checks
All feature checks are described below. Note that not all feature checks are supported by all devices.
You can find an overview as to which Vision Sensors check which features under:
Technical Data (Overview
of feature checks).
NOTE
Once installation is complete, you will find a range of application examples that provide
you with typical solutions for various inspection tasks and for the use of the individual
feature checks. After successful installation, the examples can be found in the
subdirectory:
<installation path>\AppSuite\Samples
NOTE
Jobs are compatible between devices if they work with at least the same feature checks
and identical functions for the same field of view.
Feature checks from the
identification
area are not compatible between those devices
with and without Industrial Ethernet.
Part location on contours
is supported as an
older
version
on devices with integrated Industrial Ethernet.
NOTE
Most feature checks support the
Teach
function. Initially, the contours / edges of the
sample piece will be learned or switching thresholds set absolutely or as a percent (±
10%) to the actually determined value. A relative amendment will be retained if possible
when the switching thresholds are altered manually.
The corresponding expected values will be imported during
Teach
in the case of
identification feature checks.
NOTE
Older graphics cards, such as the on-board Intel HD 3000, do not fully support OpenGL in
our experience. This can for instance result in 3D-view presentation problems with
interactive colour assistants.
NOTE
Automatic configuration of the area limits occurs with higher resolution than the display in
pixels would suggest. Rounding can result in the limit and specified value being exceeded
by one pixel in limit cases.
This can be prevented by manual configuration or readjustment of the limit areas.