Technical Documentation
VeriSens
®
v2.11.0-B4
108/429
Baumer Optronic GmbH
Radeberg, Germany
10.2.7 IP address / network
Set the IP address of the device here. There are two choices for this.
Static IP address
The device uses a set IP address.
DHCP (Dynamic Host Configuration Protocol)
If you have integrated a DHCP server in your network, the IP address is obtained there. If this does not
happen within a specific time and a timeout occurs, you can choose whether:
o
the last IP address obtained via DHCP is used
o
another fixed IP address is set
If the port
51.972
(standard) is already being used in your network, you may specify a different port for
communication between the connection of the device and the
Application Suite
.
NOTE
This port must also be set in the dialogue
Connect to device - Options
, in order to create a
connection.