If using DHCP, you can set what happens following a DHCP timeout as follows:
Use DHCP and in case of DHCP failure, use the last IP address
UDD000.000.000.000000.000.000000.000.000...
or
UDD255.255.255.255000.000.000000.000.000...
Use DHCP, set an alternative IP address
e.g.
UDD192.168.000.250255.255.255.000000.000.000.000...
(In this case, the alternative IP address is
192.168.0.250)
The response datagram is only sent once the backup has been transferred and stored in full or an error
occurs.
Structure of the Response
PLC
device
Response
R
U
0
0
R
esponse
U
pdate
2 byte ASCII hex
00 = received OK
01 = device not in Configuration mode
02 = invalid job number
03 = job could not be loaded
04 = job update still active
05 = invalid network settings
06 = invalid device name
07 = backup file device type not identical to the device
08 = user management is active
09 = device file is password protected
10 = file could not be opened for writing
11 = file write error
12 = incompatible backup
13 = only the firmware cannot be imported
other = internal fault