Technical Documentation
VeriSens
®
v2.11.0-B4
380/429
Baumer Optronic GmbH
Radeberg, Germany
Output data (PLC
device)
(originator (O) to target (T), assembly instance 109):
Byte
Group
Data element
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
0
Control and
status
Device controller
pad (0)
Operating
mode
Teach
TRG
1
Job selection
Select job number
2
Reset statistics
Reset statistics
3
Reset status (actions)
pad (0)
Reset
State SM
pad
(0)
Reset
State SP
pad (0)
Reset
State
SJ
4
Handshake for output
data
pad (0)
O -> T
HS
Flag
pad (0)
O -> T
HSWA
ACT
O -> T
HSS
ACT
5
Handshake for input
data
pad (0)
T -> O
HS
ACK
pad (0)
T -> O
HSWA
ACT
T -> O
HSS
ACT
6
Result data
Handshake for input
data
pad (0)
T -> O
HS
ACK
pad (0)
T -> O
HSWA
ACT
T -> O
HSS
ACT
7
Parameters
Actual
length of the
Parameters
Act Parameters Len
8
…
135
Parameters
Parameters (128 byte)
136
Handshake for output
data
pad (0)
O -> T
HS
Flag
pad (0)
O -> T
HSWA
ACT
O -> T
HSS
ACT
137
Trigger data
Actual length of the
trigger data
Act Trigger Data Len
138
…
201
Trigger data
Trigger data (64 byte)
202
Handshake for output
data
pad (0)
O -> T
HS
Flag
pad (0)
O -> T
HSWA
ACT
O -> T
HSS
ACT