Technical Documentation
VeriSens
®
v2.11.0-B4
175/429
Baumer Optronic GmbH
Radeberg, Germany
The current result is displayed directly in the dialog as the
Number
. The switching points designated
Min
and
Max
are adjusted on the right hand side. A graphic display is located in the middle, in which
the positions of the switching points are displayed and where they can be changed.
The right button is used to invert the result of the feature check.
Configure of the sensor as follows:
Position the search line by holding the left mouse button depressed in the image.
Min. edge length:
With short, medium or long, select the anticipated length of the sought contour to
achieve a consistent result. Using
User defined
, you may manually enter the length of an edge (5-
1000 pixels).
Transition:
You must specify whether each edge can progress from bright to dark or from dark to
bright (device dependant).
Minimum contrast:
You can also specify whether you are searching for an edge with sharp or weak
contrast.
If the feature check is to be corrected by the result of the part location, you can choose this option
here. External teach also makes it possible to retrain the feature check. Select the appropriate option
for this purpose.
Confirm your settings and return to the feature list with
OK
. Return to the feature list without making
any changes with
Cancel
.