15.4.6 Command GF
– retrieve individual files from the device
This function enables you to access individual data on the device.
Example
Structure of the command
PLC
device
Command
Parameters
G
F
0
0
0
0
G
et
F
ile
0000 = List of all jobs
01nn = Retrieve job
(nn 2 byte ASCII-Hex Job number)
02nn = Call a job using the job name
(nn:2-byte ASCII hex length of the file name + file name)
0300 = Access Logging
Structure of the Response
PLC
device
Response
R
F
0 0 0 0
0
0
0
0
0 0 0 0 F 1 2 3 ...
R
esponse
F
ile
4 bytes
ASCII-hex,
mirrored
parameters
of the GF
request
2 bytes ASCII hex: Error
code
00 = no error
occurred
01 = is not in
Configuration- or
IDLE- mode
02 = File not found
04 = last file still
being retrieved
FF = internal error
2 bytes
ASCII hex
Reserved
8 bytes ASCII hex
Length of the following
data
Dat
a